close

Cummins INCAL 2014.4 2pcs of DVD folders as follows:

DVD one contains these folders:
dvd-one
dvd-two
 Cummins INCAL 2014.4 function shows
Automotive-Calibrations-Data-Cummins-INCAL-2014.4-01-1024x716
Automotive-Calibrations-Data-Cummins-INCAL-2014.4-02-1024x718
 How copy calibrations?

In Insite, go to calibrations, select the calibration you want, right click and click copy, on a memory stick, click paste, Insite will create an Intelect folder with all the relevent files in the correct folder structure, the memory stick will work in any PC with Insite Pro, The Intelect folder can be zippd/rared and emailed, most virus scanners will trash it though.
The copied calibration will have the expiry date of the original disc.

How to use old incal calibrations with insite?

To do this you will need to modify two files namely the esdninfo.dat file and the ***.mdb file for each required calibration folder.

1: Open the following on your incal disk:

*:\INTELECT\ESDN\esdninfo.dat using notepad,

The following information should be displayed:

[Information]

Requiredbytes=100000000

Date=10058

DisplayName= "March 2010" (you can replace the display name with whatever you want to be displayed when you open the calibrations in Insite e.g DK Rulez, Cummins Calibrations e.t.c for a more custom setup.

The date is in Julian calendar format where 10 represents the year 2010 and 058 the first 58 days of the year 2010.By altering the date either 6 months before or after the present date the incal image you creating will be accepted by Insite as valid.Insite seems to to take the following month of julian date as the accepted month?

2: Open the following in Winrar

*:\INTELECT\ESDN\DATA\***\***.cmp\***.mdb where *** is the calibration file e.g ECI, CPI, or C94 etc.

When you try to open ***.mdb you will be prompted for a password try either ndse or ocec which are case sensitive (special thanks to Simmax for providing these passwords)

Open CALDATE datasheet. Modify the Caldate to match the esdninfo.dat date and time. once done save changes and calibrations are now valid. modify ***.mdb file for each calibration you require.

Using extracted files from incal cd

Many have said that it is not possible to use incal files without the complete incal disk but here is a procedure on how to do it. (P.S this is whilst using a valid incal disk).

Create a new folder and label it INTELECT. In the INTELECT folder create another folder and this time label it ESDN. Inside this second folder you must create another folder and call it DATA. Extract the esdninfo.dat file from your valid incal disk and place it in the ESDN file of the image you are creating. At this point your ESDN folder should contain two files namely DATA folder and esdninfo.dat file.

In the DATA folder place the calibration folders you require after extracting from incal disk. I used the ECI folder sent to me by hpcummins in this example. You should include all calibration folders you intend to use in this image before proceeding. You will also have to extract the esdndata.cmp file from your incal disk and place it in your DATA folder.

At this point your image is complete and you can now copy this folder INTELECT to a flash disk or into your calibration workspace on your harddrive and it is ready for use.

About this point of view, another engineer said as follows:

I think we..never stop to works with the last incal disck...every time we can find!!!!!!!!

because cummins makes several changes to ecm..in special to isxs and ism.

if we just need program the ecms or works with trucks from 2005 or back is not problem...ecm can be update with 2009 or others disck with date back keygen.

with the 2005's to newers we cant stop watching the new disck..hardware inside of ecm need to have patchs and updates....every time.

and with calter ..is not problem you can use any disck..in parts of it or complete...is not problem..if the file is complete.

What I have to do to insite as opening and into selection of these calibrations are there, or whether it will have to be connected to a ecm insite?

Well firstly you will need to have insite activated at pro-level. You can check this by entering into your tools menu and then checking what security level you have active. If it is not at pro or pro-plus level you will have to ask for activation codes on the insite threads.

Secondly you will require an active incal disk that has the calibrations you require. To open calibrations select the calibration selection menu in insite and you will find that the drive where you inserted the incal disk will be shown and you can open it to view calibrations without having to connect to ecm. You can also create your own incal image and place it in the calibration workspace folder on your harddrive like I described in earlier posts in this thread.

arrow
arrow
    文章標籤
    Cummins INCAL 2014.4
    全站熱搜

    buyobdii 發表在 痞客邦 留言(0) 人氣()